Fiber-Optic Technologies

  • Sample Chapter is provided courtesy of Cisco Press.
  • Date: Apr 23, 2004.

Chapter Description

Vivek Alwayn discusses in this chapter the increasing demand of optical-fiber and its wide spread applications ranging from global networks to desktop computers.

Fiber Span Analysis

Span analysis is the calculation and verification of a fiber-optic system's operating characteristics. This encompasses items such as fiber routing, electronics, wavelengths, fiber type, and circuit length. Attenuation and nonlinear considerations are the key parameters for loss-budget analysis. Before implementing or designing a fiber-optic circuit, a span analysis is recommended to make certain the system will work over the proposed link. Both the passive and active components of the circuit have to be included in the loss-budget calculation. Passive loss is made up of fiber loss, connector loss, splice loss, and losses involved with couplers or splitters in the link. Active components are system gain, wavelength, transmitter power, receiver sensitivity, and dynamic range.

Nonlinear effects occur at high bit rates and power levels. These effects must be mitigated using compensators, and a suitable budget allocation must be made during calculations.

The overall span loss, or link budget as it is sometimes called, can be determined by using an optical meter to measure true loss or by computing the loss of system components. The latter method considers the loss associated with span components, such as connectors, splices, patch panels, jumpers, and the optical safety margin. The safety margin sets aside 3 dB to compensate for component aging and repair work in event of fiber cut. Adding all of these factors to make sure their sum total is within the maximum attenuation figure ensures that the system will operate satisfactorily. Allowances must also be made for the type of splice, the age and condition of the fiber, equipment, and the environment (including temperature variations).

NOTE

Considerations for temperature effects associated with most fibers usually yield ?1 dB that could be optionally included in optical loss-budget calculations.

Transmitter Launch Power

Power measured in dBm at a particular wavelength generated by the transmitter LED or LD used to launch the signal is known as the transmitter launch power. Generally speaking, the higher the transmitter launch power, the better. However, one must be wary of receiver saturation, which occurs when the received signal has a very high power content and is not within the receiver's dynamic range. If the signal strength is not within the receiver's dynamic range, the receiver cannot decipher the signal and perform an OE conversion. High launch powers can offset attenuation, but they can cause nonlinear effects in the fiber and degrade system performance, especially at high bit rates.

Receiver Sensitivity and Dynamic Range

Receiver sensitivity and dynamic range are the minimum acceptable value of received power needed to achieve an acceptable BER or performance. Receiver sensitivity takes into account power penalties caused by use of a transmitter with worst-case values of extinction ratio, jitter, pulse rise times and fall times, optical return loss, receiver connector degradations, and measurement tolerances. The receiver sensitivity does not include power penalties associated with dispersion or with back reflections from the optical path. These effects are specified separately in the allocation of maximum optical path penalty. Sensitivity usually takes into account worst-case operating and end-of-life (EOL) conditions. Receivers have to cope with optical inputs as high as –5 dBm and as low as –30 dBm. Or stated differently, the receiver needs an optical dynamic range of 25 dB.

Power Budget and Margin Calculations

To ensure that the fiber system has sufficient power for correct operation, you need to calculate the span's power budget, which is the maximum amount of power it can transmit. From a design perspective, worst-case analysis calls for assuming minimum transmitter power and minimum receiver sensitivity. This provides for a margin that compensates for variations of transmitter power and receiver sensitivity levels.

Power budget (PB) = Minimum transmitter power (PTMIN) – Minimum receiver sensitivity (PRMIN)

You can calculate the span losses by adding the various linear and nonlinear losses. Factors that can cause span or link loss include fiber attenuation, splice attenuation, connector attenuation, chromatic dispersion, and other linear and nonlinear losses. Table 3-1 provides typical attenuation characteristics of various kinds of fiber-optic cables. Table 3-2 provides typical insertion losses for various connectors and splices. Table 3-3 provides the margin requirement for nonlinear losses along with their usage criteria. For information about the actual amount of signal loss caused by equipment and other factors, refer to vendor documentation.

Span loss (PS) = (Fiber attenuation * km) + (Splice attenuation * Number of splices) +
(Connector attenuation * Number of connectors) + (In-line device losses) + (Nonlinear losses) + (Safety margin) 

Table 3-1 Typical Fiber-Attenuation Characteristics

Mode

Material

Refractive Index Profile

λ (nm)

Diameter (m)

Attenuation (dB/km)

Multimode

Glass

Step

800

62.5/125

5.0

Multimode

Glass

Step

850

62.5/125

4.0

Multimode

Glass

Graded

850

62.5/125

3.3

Multimode

Glass

Graded

850

50/125

2.7

Mode

Material

Refractive Index Profile

λ (nm)

Diameter (m)

Attenuation (dB/km)

Multimode

Glass

Graded

1310

62.5/125

0.9

Multimode

Glass

Graded

1310

50/125

0.7

Multimode

Glass

Graded

850

85/125

2.8

Multimode

Glass

Graded

1310

85/125

0.7

Multimode

Glass

Graded

1550

85/125

0.4

Multimode

Glass

Graded

850

100/140

3.5

Multimode

Glass

Graded

1310

100/140

1.5

Multimode

Glass

Graded

1550

100/140

0.9

Multimode

Plastic

Step

650

485/500

240

Multimode

Plastic

Step

650

735/750

230

Multimode

Plastic

Step

650

980/1000

220

Multimode

PCS

Step

790

200/350

10

Single-mode

Glass

Step

650

3.7/80 or 125

10

Single-mode

Glass

Step

850

5/80 or 125

2.3

Single-mode

Glass

Step

1310

9.3/125

0.5

Single-mode

Glass

Step

1550

8.1/125

0.2

Single-mode

Glass

Dual Step

1550

8.1/125

0.2


Table 3-2 Component Loss Values

Component

Insertion Loss

Connector Type

 

SC

0.5 dB

ST

0.5 dB

FC

0.5 dB

LC

0.5 dB

MT-RJ

0.5 dB

MTP/MPO

0.5 dB

Splice

 

Mechanical

0.5 dB

Fusion

0.02 dB

Fiber patch panel

2.0 dB


NOTE

Typical multimode connectors have insertion losses between 0.25 dB and 0.5 dB, whereas single-mode connectors that are factory made and fusion spliced onto the fiber cable will have losses between 0.15 dB and 0.25 dB. Field-terminated single-mode connectors can have losses as high as 1.0 dB.

Table 3-3 Reference Margin Values

Characteristic

Loss Margin

Bit Rate

Signal Power

Dispersion margin

1 dB

Both

Both

SPM margin

0.5 dB

High

High

XPM margin (WDM)

0.5 dB

High

High

FWM margin (WDM)

0.5 dB

Both

High

SRS/SBS margin

0.5 dB

High

High

PMD margin

0.5 dB

High

Both


The next calculation involves the power margin (PM), which represents the amount of power available after subtracting linear and nonlinear span losses (PS) from the power budget (PB). A PM greater than zero indicates that the power budget is sufficient to operate the receiver. The formula for power margin (PM) is as follows:

Power margin (PM) = Power budget (PB) – Span loss (PS)

To prevent receiver saturation, the input power received by the receiver, after the signal has undergone span loss, must not exceed the maximum receiver sensitivity specification (PRMAX). This signal level is denoted as (PIN). The maximum transmitter power (PTMAX) must be considered as the launch power for this calculation. The span loss (PS) remains constant.

Input power (PIN) = Maximum transmitter power (PTMAX) – Span loss (PS)

The design equation

Input power (PIN) <= Maximum receiver sensitivity (PRMAX)

must be satisfied to prevent receiver saturation and ensure system viability. If the input power (PIN) is greater than the maximum receiver sensitivity (PRMAX), passive attenuation must be considered to reduce signal level and bring it within the dynamic range of the receiver.

Case 1: MMF Span Analysis

Consider the fiber-optic system shown in Figure 3-21 operating at OC-3 (155 Mbps). The minimum optical transmitter launch power is –12.5 dBm, and the maximum optical transmitter launch power is –2 dBm at 1310 nm. The minimum receiver sensitivity is –30 dBm, and the maximum receiver sensitivity is –3 dBm at 1310 nm. The example assumes inclusion of two patch panels in the path, two mechanical splices, with the system operating over 2 km of graded index 50/125-m multimode fiber-optic cable. Refer to Tables 3-1, 3-2, and 3-3 for appropriate attenuation, component, and nonlinear loss values.

Figure 21Figure 3-21 MMF Span Analysis

The system operates at 155 Mbps or approximately 155 MHz. At such bit rates, there is no need to consider SPM, PMD, or SRS/SBS margin requirements. Because the link is a single-wavelength system, there is no need to include XPM or FWM margins. However, it is safe to consider the potential for a degree of chromatic dispersion, because chromatic dispersion occurs at all bit rates. The span analysis and viability calculations over the link are computed as follows.

Component

dB Loss

Minimum transmitter launch power (PTMIN)

–12.5 dBm

Minimum receiver sensitivity (PRMIN)

–30 dBm

Power Budget (PB) = (PTMIN – PRMIN)

17.5 dB


Component

dB Loss

MMF graded index 50/125-m cable at 1310 nm (2 km * 0.7 dB/km)

1.4 dB

ST connectors (2 * 0.5 dB/connector)

1 dB

Mechanical splice (2 * 0.5 dB/splice)

1 dB

Patch panels (2 * 2 dB/panel)

4 dB

Dispersion margin

1 dB

Optical safety and repair margin

3 dB

Total Span Loss (PS)

11.4 dB


Power margin (PM) = Power budget (PB) – Span loss (PS)
PM = 17.5 dB – 11.4 dB
PM = 6.1 dB > 0 dB

In the preceding example, notice that the 11.4-dB total span loss is well within the 17.5-dB power budget or maximum allowable loss over the span.

To prevent receiver saturation, the input power received by the receiver, after the signal has undergone span loss, must not exceed the maximum receiver sensitivity specification (PRMAX). This signal level is denoted as (PIN). The maximum transmitter power (PTMAX) must be considered as the launch power for this calculation. The span loss (PS) remains constant.

Input power (PIN) = Maximum transmitter power (PTMAX) – Span loss (PS)
PIN = –2 – 11.4
PIN = –13.4 dBm
–13.4 dBm (PIN) <= –3 dBm

This satisfies the receiver sensitivity design equation and ensures viability of the optical system at an OC-3 rate over 2 km without the need for amplification or attenuation.

Case 2: SMF Span Analysis

Consider the fiber-optic system in Figure 3-22 operating at OC-192 (9.953 Gbps). The minimum optical transmitter launch power is –7.5 dBm, and the maximum optical transmitter launch power is 0 dBm at 1550 nm. The minimum receiver sensitivity is –30 dBm, and the maximum receiver sensitivity is –3 dBm at 1550 nm. The example assumes inclusion of two patch panels in the path, four fusion splices, with the system operating over 25 km of step index 8.1/125-m SMF cable. Refer to Tables 3-1, 3-2, and 3-3 for appropriate attenuation, component, and nonlinear loss values.

Figure 22Figure 3-22 SMF Link-Budget Example

The system is operating at 9.953 Gbps or approximately 10 GHz. At such high bit rates, SPM, PMD, and SRS/SBS margin requirements must be taken into consideration. Also consider the potential for a degree of chromatic dispersion. Because the link is a single-wavelength system, there is no need to include XPM or FWM margins. The link loss and viability calculations over the link are computed as follows.

Component

dB Loss

Minimum transmitter launch power (PTMIN)

–7.5 dBm

Minimum receiver sensitivity (PRMIN)

–30 dBm

Power Budget (PB) = (PTMIN – PRMIN)

22.5 dB


Component

dB Loss

SMF step index 8.1/125-m cable at 1550 nm (50 km * 0.2 dB/km)

10 dB

LC connectors (2 * 0.5 dB/connector)

1.0 dB

Fusion splices (8 * 0.02 dB/splice)

0.16 dB

Patch panels (2 * 2 dB/panel)

4 dB

Dispersion margin

1 dB

SPM margin

0.5 dB

PMD margin

0.5 dB

SRS/SBS margin

0.5 dB

Optical safety and repair margin

3 dB

Total Span Loss (PS)

20.66 dB


Power margin (PM) = Power budget (PB) – Span loss (PS)
PM = 22.5 dB – 20.66 dB
PM = 1.84 dB > 0 dB

In the example, notice that the 20.66-dB total span loss is well within the 22.5-dB power budget or maximum allowable loss over the span. To prevent receiver saturation, the input power received by the receiver, after the signal has undergone span loss, must not exceed the maximum receiver sensitivity specification (PRMAX). This signal level is denoted as (PIN). The maximum transmitter power (PTMAX) must be considered as the launch power for this calculation. The span loss (PS) remains constant.

Input power (PIN) = Maximum transmitter power (PTMAX) – Span loss (PS)
PIN = 0 – 20.66 dBm
PIN = –20.66 dBm
–20.66 dBm (PIN) <= –3 dBm (PRMAX)

This satisfies the receiver sensitivity design equation and ensures viability of the optical system at an OC-192 rate over 50 km without the need for amplification or attenuation. Note, however, that this example has not considered dispersion calculations or dispersion compensation. Dispersion compensation units insert their own loss component into the overall span.

NOTE

In the preceding example, various margins for nonlinear effects were included in the span loss calculation. This is not necessary if the maximum power on the SMF is kept below +10 dBm to avoid nonlinear effects on the transmission signal. For dispersion-compensated spans, the maximum power on the dispersion compensation module (DCU) must be kept below +4 dBm to avoid nonlinear effects on DCU.

Cisco Press Promotional Mailings & Special Offers

I would like to receive exclusive offers and hear about products from Cisco Press and its family of brands. I can unsubscribe at any time.

Overview

Pearson Education, Inc., 221 River Street, Hoboken, New Jersey 07030, (Pearson) presents this site to provide information about Cisco Press products and services that can be purchased through this site.

This privacy notice provides an overview of our commitment to privacy and describes how we collect, protect, use and share personal information collected through this site. Please note that other Pearson websites and online products and services have their own separate privacy policies.

Collection and Use of Information

To conduct business and deliver products and services, Pearson collects and uses personal information in several ways in connection with this site, including:

Questions and Inquiries

For inquiries and questions, we collect the inquiry or question, together with name, contact details (email address, phone number and mailing address) and any other additional information voluntarily submitted to us through a Contact Us form or an email. We use this information to address the inquiry and respond to the question.

Online Store

For orders and purchases placed through our online store on this site, we collect order details, name, institution name and address (if applicable), email address, phone number, shipping and billing addresses, credit/debit card information, shipping options and any instructions. We use this information to complete transactions, fulfill orders, communicate with individuals placing orders or visiting the online store, and for related purposes.

Surveys

Pearson may offer opportunities to provide feedback or participate in surveys, including surveys evaluating Pearson products, services or sites. Participation is voluntary. Pearson collects information requested in the survey questions and uses the information to evaluate, support, maintain and improve products, services or sites; develop new products and services; conduct educational research; and for other purposes specified in the survey.

Contests and Drawings

Occasionally, we may sponsor a contest or drawing. Participation is optional. Pearson collects name, contact information and other information specified on the entry form for the contest or drawing to conduct the contest or drawing. Pearson may collect additional personal information from the winners of a contest or drawing in order to award the prize and for tax reporting purposes, as required by law.

Newsletters

If you have elected to receive email newsletters or promotional mailings and special offers but want to unsubscribe, simply email information@ciscopress.com.

Service Announcements

On rare occasions it is necessary to send out a strictly service related announcement. For instance, if our service is temporarily suspended for maintenance we might send users an email. Generally, users may not opt-out of these communications, though they can deactivate their account information. However, these communications are not promotional in nature.

Customer Service

We communicate with users on a regular basis to provide requested services and in regard to issues relating to their account we reply via email or phone in accordance with the users' wishes when a user submits their information through our Contact Us form.

Other Collection and Use of Information

Application and System Logs

Pearson automatically collects log data to help ensure the delivery, availability and security of this site. Log data may include technical information about how a user or visitor connected to this site, such as browser type, type of computer/device, operating system, internet service provider and IP address. We use this information for support purposes and to monitor the health of the site, identify problems, improve service, detect unauthorized access and fraudulent activity, prevent and respond to security incidents and appropriately scale computing resources.

Web Analytics

Pearson may use third party web trend analytical services, including Google Analytics, to collect visitor information, such as IP addresses, browser types, referring pages, pages visited and time spent on a particular site. While these analytical services collect and report information on an anonymous basis, they may use cookies to gather web trend information. The information gathered may enable Pearson (but not the third party web trend services) to link information with application and system log data. Pearson uses this information for system administration and to identify problems, improve service, detect unauthorized access and fraudulent activity, prevent and respond to security incidents, appropriately scale computing resources and otherwise support and deliver this site and its services.

Cookies and Related Technologies

This site uses cookies and similar technologies to personalize content, measure traffic patterns, control security, track use and access of information on this site, and provide interest-based messages and advertising. Users can manage and block the use of cookies through their browser. Disabling or blocking certain cookies may limit the functionality of this site.

Do Not Track

This site currently does not respond to Do Not Track signals.

Security

Pearson uses appropriate physical, administrative and technical security measures to protect personal information from unauthorized access, use and disclosure.

Children

This site is not directed to children under the age of 13.

Marketing

Pearson may send or direct marketing communications to users, provided that

  • Pearson will not use personal information collected or processed as a K-12 school service provider for the purpose of directed or targeted advertising.
  • Such marketing is consistent with applicable law and Pearson's legal obligations.
  • Pearson will not knowingly direct or send marketing communications to an individual who has expressed a preference not to receive marketing.
  • Where required by applicable law, express or implied consent to marketing exists and has not been withdrawn.

Pearson may provide personal information to a third party service provider on a restricted basis to provide marketing solely on behalf of Pearson or an affiliate or customer for whom Pearson is a service provider. Marketing preferences may be changed at any time.

Correcting/Updating Personal Information

If a user's personally identifiable information changes (such as your postal address or email address), we provide a way to correct or update that user's personal data provided to us. This can be done on the Account page. If a user no longer desires our service and desires to delete his or her account, please contact us at customer-service@informit.com and we will process the deletion of a user's account.

Choice/Opt-out

Users can always make an informed choice as to whether they should proceed with certain services offered by Cisco Press. If you choose to remove yourself from our mailing list(s) simply visit the following page and uncheck any communication you no longer want to receive: www.ciscopress.com/u.aspx.

Sale of Personal Information

Pearson does not rent or sell personal information in exchange for any payment of money.

While Pearson does not sell personal information, as defined in Nevada law, Nevada residents may email a request for no sale of their personal information to NevadaDesignatedRequest@pearson.com.

Supplemental Privacy Statement for California Residents

California residents should read our Supplemental privacy statement for California residents in conjunction with this Privacy Notice. The Supplemental privacy statement for California residents explains Pearson's commitment to comply with California law and applies to personal information of California residents collected in connection with this site and the Services.

Sharing and Disclosure

Pearson may disclose personal information, as follows:

  • As required by law.
  • With the consent of the individual (or their parent, if the individual is a minor)
  • In response to a subpoena, court order or legal process, to the extent permitted or required by law
  • To protect the security and safety of individuals, data, assets and systems, consistent with applicable law
  • In connection the sale, joint venture or other transfer of some or all of its company or assets, subject to the provisions of this Privacy Notice
  • To investigate or address actual or suspected fraud or other illegal activities
  • To exercise its legal rights, including enforcement of the Terms of Use for this site or another contract
  • To affiliated Pearson companies and other companies and organizations who perform work for Pearson and are obligated to protect the privacy of personal information consistent with this Privacy Notice
  • To a school, organization, company or government agency, where Pearson collects or processes the personal information in a school setting or on behalf of such organization, company or government agency.

Links

This web site contains links to other sites. Please be aware that we are not responsible for the privacy practices of such other sites. We encourage our users to be aware when they leave our site and to read the privacy statements of each and every web site that collects Personal Information. This privacy statement applies solely to information collected by this web site.

Requests and Contact

Please contact us about this Privacy Notice or if you have any requests or questions relating to the privacy of your personal information.

Changes to this Privacy Notice

We may revise this Privacy Notice through an updated posting. We will identify the effective date of the revision in the posting. Often, updates are made to provide greater clarity or to comply with changes in regulatory requirements. If the updates involve material changes to the collection, protection, use or disclosure of Personal Information, Pearson will provide notice of the change through a conspicuous notice on this site or other appropriate way. Continued use of the site after the effective date of a posted revision evidences acceptance. Please contact us if you have questions or concerns about the Privacy Notice or any objection to any revisions.

Last Update: November 17, 2020